Part No | Nominal Voltage | Rated Capacity | Internal Resistance | Discharge Rate | Dimension(mm) | Weight(g) | |
Diameter | Height | ||||||
GSL-LFP26650-3.2V-2500mAh | 3.2V | 2500mAh | <10 m Ω | 20C | 26.3±0.1 | 65.2±0.2 | 87 |
GSL-LFP26650-3.2V-3000mAh | 3.2V | 2500mAh | <10 m Ω | 10C | 26.3±0.1 | 65.2±0.2 | 85 |
GSL-LFP26650-3.2V-3200mAh | 3.2V | 2500mAh | <25 m Ω | 3C | 26.3±0.1 | 65.2±0.2 | 85 |
GSL-LFP26650-3.2V-3300mAh | 3.2V | 2500mAh | <25 m Ω | 3C | 26.3±0.1 | 65.2±0.2 | 85 |
GSL-LFP26650-3.2V-3400mAh | 3.2V | 2500mAh | <25 m Ω | 3C | 26.3±0.1 | 65.2±0.2 | 85 |
GSL-LFP26650-3.2V-3600mAh | 3.2V | 2500mAh | <25 m Ω | 3C | 26.3±0.1 | 65.2±0.2 | 85 |
GSL-LFP26650-3.2V-3800mAh | 3.2V | 2500mAh | <25 m Ω | 3C | 26.3±0.1 | 65.2±0.2 | 87 |
GSL-LFP26650-3.2V-4000mAh | 3.2V | 2500mAh | <25 m Ω | 3C | 26.3±0.1 | 65.2±0.2 | 88 |
GSL ENERGY has been awarded as Hi-Tech Company of Guangdong Province,and products are designed to be safe,reliable and competitively priced.All our products are designed and manufactured to the highest standards and meet or exceed industry safety and environmental standards including:ISO9001,IEC62133,UL1642/UL2054,CE,RoHS.
PRODUCT ADVANTAGE
Characteristics Curves
● Long cycle life ● Superior safety ● Smaller size ● Lighter Weight
APPLICATION
Lithium Battery Packs made by LiFePO4 3.2v 26650 cells are applicable for the following
Application:
1.Electric vehicles and charging stations,tourist coaches,yachts,wind and solar energy storage power,traffic signals.
2.Solar hybrid street lighting,UPS power supply, home storage.
3.Coal,disaster relief emergency,weather radar,electricity,smart grid,communication base stations.
4.Hospitals,finance,telecommunications,system critical backup power systems.
SUPER SAFETY TEST
Passed the below abuse and safety test-short-circuit, dropping, nail penetration, impact, crush, thermal shock, over-charge,over-discharge: no fire, no explosion with stable chemical structure.
PACKING
WHY CHOOSE US
◆ Experience--More than 12 years Specialized in lithium battery, Leaders of Lithium Lifepo4 Battery.
◆ Certification--CE,UL,MSDS,Test Report from National Center For Quality Supervision and Inspection of Battery Products approved.
◆ Quality Control-- 37 production process,7 steps quality check to promise stable quality and high reliability for you.
◆ Best Material-- Insist on choosing top quality cell, material and accessories,lithium battery last longer time.
◆ Fresh battery-- All battery is fresh Production.
Toroidal Precision Micro Current Transformer For Electricity Meter
Current Transformers
The E-TAL type series for current transformers comprises various versions for a large number of applications. Strong insulation voltage between the primary and the secondary, up to 4kV/1min, without breakdown.
The insulation resistance should be bigger than 1000MΩ between the primary and secondary windings.
Best-performance core designs in close cooperation with our customers.
Technical support including simulation software to optimize the circuit topology.
AC Current Transformers
Features:
• AC measurement capacity is 20% higher than rated current
• Negligible small amplitude error
• Extreme linear, easily compensable phase curve
• Low temperature dependence
• It accords with IEC 60044-1 0.1class, 0.2class, 0.5class
• RoHS Compliance is available on request
Characteristics:
• Operating Temp.: -40℃ ~ +85℃ or on request
• Dielectric strength: 4KVAC/60S
• Accuracy: 0.1Class, AC Error < 0.1%, Phase shift <15'
• Operating Frequency: 20Hz~10kHz
• Insulation resistance: >500MΩ (500VDC)
1. Pin Type
• Easy fixing on PCB
• Small volume, easy for installation
• Simple assembly, saving production cost
• Big inner hole, suitable for any primary cables and busbars
• Different casing colors available on request
Specifications
E-TAL Products | Primary Current (A) | Turns Ratio | Burden Resistance (Ω) | AC Error (%) | Phase Shift | Accuracy |
EAC006C-P | 6 | 1:2500 | 10/12.5/15/20 | <0.1 | <15 | ≤0.1 |
EAC010C-P | 10 | |||||
EAC020C-P | 20 | |||||
EAC030C-P | 30 | |||||
EAC040C-P | 40 | |||||
EAC060C-P | 60 | |||||
EAC080C-P | 80 | |||||
EAC100C-P | 100 | |||||
EAC120C-P | 120 | |||||
EAC150C-P | 150 | |||||
EAC200C-P | 200 |
Dimensions(Unit:mm)
Primary Current | DIN | L | W | H | S1 | S2 | S3 |
2A ~ 40A | 6.8 | 24 | 11 | 25 | 15 | 19 | 10 |
20A ~ 80A | 8.2 | 30 | 18 | 30 | 16 | 19 | 15 |
100A ~ 200A | 13 | 37.3 | 15.3 | 38.3 | 25 | 33 | 13 |
Note: To simplify your design process please sent requirements to us.
2. Casing Type
• Easy fixing inside meter
• Small volume, easy for installation
• Simple assembly, saving production cost
• Big inner hole, easy connection to any primary
• cables and bus bars of latching relay
• Different casing colors available on request
Specifications
E-TAL Products | Primary Current (A) | Turns Ratio | Burden Resistance (Ω) | AC Error (%) | Phase Shift | Accuracy |
EAC006C | 6 | 1:2500 | 10/12.5/15/20 | <0.1 | <15 | ≤0.1 |
EAC010C | 10 | |||||
EAC020C | 20 | |||||
EAC040C | 40 | |||||
EAC060C | 60 | |||||
EAC080C | 80 | |||||
EAC100C | 100 | |||||
EAC120C | 120 | |||||
EAC150C | 150 | |||||
EAC200C | 200 | |||||
EAC400C | 400 | 1:4000 | 5 |
Dimensions(Unit:mm)
Primary Current | DIN | L | W | H | Secondary Wire |
2A ~ 40A | 6.5 | 24 | 11 | 25 | Or on request |
10A ~ 80A | 8.2 | 30 | 18 | 30 | |
100A ~ 200A | 13 | 38 | 15 | 39 | |
200A | 28 | 54 | 20 | 54 | |
400A | 39 | 74 | 25 | 74 |
Note: To simplify your design process please sent requirements to us.
3. Bushing Type
• Easy fixing inside meter
• Small volume, easy for installation
• Wider measurement range, up to 400A
• Big inner hole, easy connection to any primary
cables and bus bars of latching relay
• Different casing colors available on request
Specifications
E-TAL Products | Primary Current (A) | Turns Ratio | Burden Resistance (Ω) | AC Error (%) | Phase Shift | Accuracy |
EAC006R | 6 | 1:2500 | 10/12.5/15/20 | <0.1 | <15 | ≤0.1 |
EAC010R | 10 | |||||
EAC020R | 20 | |||||
EAC040R | 40 | |||||
EAC060R | 60 | |||||
EAC080R | 80 | |||||
EAC100R | 100 | |||||
EAC200R | 200 | |||||
EAC400R | 400 | 1:4000 | 10 |
Dimensions(Unit:mm)
Primary Current | DIN | DOUT | W | Secondary Wire |
2A ~ 10A | 10 | 25 | 10.5 | UL1007 24AWG Or on request |
10A ~ 60A | 10 | 28 | 17 | |
60A ~ 100A | 10.5 | 27.5 | 16 | |
80A ~ 100A | 12 | 30 | 18 | |
200A ~ 400A | 29 | 53 | 19 |
Note: To simplify your design process please sent requirements to us.
DC Current Transformers
Features:
• Special double-core structure
• Resistance to DC component
• AC measurement capacity is 20% higher than rated current
• DC measurement capacity is more than 75% of the rated AC
• Negligible small amplitude error
• Extreme linear, easily compensable phase curve
• Low temperature dependence
• It accords with IEC 60044-1 0.1class, 0.2class, 0.5class
• RoHS Compliance is available on request
Characteristics:
• Operating Temp.: -40℃ ~ +85℃ or on request
• Dielectric strength: 4KVAC/60S
• Accuracy: 0.1Class, AC Error < 0.1%, Phase shift <15'
• Operating Frequency: 20Hz~10kHz
• Insulation resistance: >500MΩ (500VDC)
1. Pin Type
• Easy fixing on PCB
• Small volume, easy for installation
• Simple assembly, saving production cost
• Big inner hole,
suitable for any primary cables and busbars
• Different casing colors available on request
Specifications
E-TAL Products | Primary Current (A) | Turns Ratio | Burden Resistance (Ω) | AC Error (%) | Phase Shift | Accuracy | |
AC | DC | ||||||
EDC006C-P | 6 | 6/√2 | 1:2500 | 10/12.5/15/20 | <0.1 | <15 | ≤0.1 |
EDC060C-P | 60 | 60/√2 | |||||
EDC100C-P | 100 | 100/√2 | |||||
EDC120C-P | 120 | 120/√2 |
Dimensions(Unit:mm)
Primary Current | DIN | L | W | H | S1 | S2 | S3 |
2A ~ 60A | 8.2 | 30 | 18.8 | 30 | 16 | 19 | 15 |
40A ~ 100A | 9 | 26 | 17 | 28 | 15 | 19.1 | 15.5 |
60A ~ 120A | 13 | 38 | 15 | 39 | 25 | 33 | 13 |
100A ~ 120A | 12.7 | 41.5 | 18.5 | 42 | 25 | 33 | 13 |
Note: To simplify your design process please sent requirements to us.
2. Casing Type
• Easy fixing inside meter
• Small volume, easy for installation
• Simple assembly, saving production cost
• Big inner hole, easy connection to any primary
• Cables and bus bars of latching relay
• Different casing colors available on request
Specifications
E-TAL Products | Primary Current (A) | Turns Ratio | Burden Resistance (Ω) | AC Error (%) | Phase Shift | Accuracy | |
AC | DC | ||||||
EDC002C | 6 | 6/√2 | 1:2500 | 10/12.5/15/20 | <0.1 | <15 | ≤0.1 |
EDC006C | 10 | 10/√2 | |||||
EDC040C | 40 | 40/√2 | |||||
EDC060C | 60 | 60/√2 | |||||
EDC080C | 80 | 80/√2 | |||||
EDC100C | 100 | 100/√2 | |||||
EDC120C | 120 | 120/√2 |
Dimensions(Unit:mm)
Primary Current | DIN | L | W | H | Secondary Wire |
2A ~ 60A | 8.2 | 30.7 | 17.4 | 30.7 | UL1007 24AWG Or on request |
10A ~ 80A | 8 | 30 | 14.5 | 31 | |
80A ~ 100A | 11 | 34 | 19 | 34 | |
60A ~ 120A | 13 | 37.3 | 15.3 | 38.3 | |
100A ~ 120A | 10.5 | 34.5 | 19.5 | 34.5 |
Note: To simplify your design process please sent requirements to us.
3. Bushing Type
• Easy fixing inside meter
• Small volume, easy for installation
• Wider measurement range, up to 400A
• Big inner hole, easy connection to any primary
cables and bus bars of latching relay
• Different casing colors available on request
Specifications
E-TAL Products | Primary Current (A) | Turns Ratio | Burden Resistance (Ω) | AC Error (%) | Phase Shift | Accuracy |
EDC006R | 6 | 1:2500 | 10/12.5/15/20 | <0.1 | <15 | ≤0.1 |
EDC020R | 20 | |||||
EDC040R | 40 | |||||
EDC060R | 60 | |||||
EDC080R | 80 | |||||
EDC100R | 100 | |||||
EDC200R | 200 | |||||
EDC400R | 400 | 1:4000 | 10 |
Dimensions(Unit:mm)
Primary Current | DIN(±3) | DOUT(±3) | W(±3) | Secondary Wire |
2A ~ 10A | 10 | 29 | 20 | UL1007 24AWG Or on request |
40A ~ 80A | 11.5 | 30 | 16 | |
80A ~ 120A | 10 | 30 | 17 | |
80A ~ 100A | 12 | 30 | 18 | |
100A ~ 120A | 10 | 34 | 24 | |
120A ~ 200A | ≥14 | ≤42 | ≤25 | |
400A | 38 | 72 | 28 |