loading

 sales@gsl-energy.com     0086 13923720280

High Voltage 3Phase Hybrid Inverter GSL-29.9/ 30/ 40/ 50KHV-3PH 1
High Voltage 3Phase Hybrid Inverter GSL-29.9/ 30/ 40/ 50KHV-3PH 2
High Voltage 3Phase Hybrid Inverter GSL-29.9/ 30/ 40/ 50KHV-3PH 3
High Voltage 3Phase Hybrid Inverter GSL-29.9/ 30/ 40/ 50KHV-3PH 1
High Voltage 3Phase Hybrid Inverter GSL-29.9/ 30/ 40/ 50KHV-3PH 2
High Voltage 3Phase Hybrid Inverter GSL-29.9/ 30/ 40/ 50KHV-3PH 3

High Voltage 3Phase Hybrid Inverter GSL-29.9/ 30/ 40/ 50KHV-3PH

An on-grid inverter’s main job is to convert DC power generated from the PV array into usable AC power. Hybrid inverters go a step further and work with batteries to store excess power as well. In the developing world, hybrid inverters are more of a necessity to compensate for weak or intermittent grids or a lack of grid electricity all together.

    oops...!

    no product data.

    Go to homepage
    GSL ENERGY Thress Phase_GSL-29.9,30,35,40,50KHV-3PH-EU__datasheet.pdf
    GSL ENERGY Thress Phase_GSL-29.9,30,35,40,50KHV-3PH-EU__datasheet.pdf


    ModelGSL-29.9KHV-3PHGSL-30KHV-3PHGSL-35KHV-3PH
    GSL-40KHV-3PHGSL-50KGV-3PH
    Battery Input Data

    Battery Type

    Li-Ion
    Battery Voltage Range (V)160~800
    Max.Charging Current (A)
    50+50
    Max.Discharging Current (A)
    50+50
    Number of Battery Input
    2
    Charging Strategy for Li-on Battery
    Self-adaption to BMS
    PV String Input Data
    Max.DC Input Power (W)3887039000455005200065000
    Max.DC Input Voltage (V)1000
    Start-up voltage (V)180
    MPPT Range (V)150-850
    Rated DC Input Voltage (V)600
    Max. Operating PV Input Current (A)36+36+3636+36+36+36
    Max. Input Short-Circuit Current (A) 55+55+5555+55+55+55

    No.of MPPT Trackers/ 

    No.of String Per MPPT Tracker

    3/2+2+24/2+2+2+2
    AC Output Data
    Rated AC Output and UPS Power (W)299003000035000
    4000050000
    Max. AC Output Power (W)29900
    330003850044000
    55000
    AC Output Rated Current (A)37.9/36.345.5/43.553.1/50.860.7/5875.8/72.5
    Max. AC Output Rated Current (A)45.4/43.450/43.558.4/55.866.7/63.883.4/79.7
    Max. Three-phase Unbalanced Output Current (A)606060
    7083.3
    Max. Continuous AC Passthrough (A)200
    Peak Power (off grid)1.5 time of rated power, 10 S
    Power Factor Adjustment Range0.8 leading to 0.8 lagging
    Rated Input/Output Voltage/Range (V)220/380V, 230/400V 0.85Un-1.1Un
    Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
    Grid Connection Form3L+N+PE
    Total Current Harmonic Distortion THDi<3% (of nominal power)
    DC Component of Grid<0.5% In
    Efficiency
    Max. Efficiency

    97.60%

    Euro Efficiency97.00%
    MPPT Efficiency99.00%
    Equipment Protection
    IntegratedDC Polarity Reverse Connection Protection, AC Output Overcurrent Protection AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
    Surge Protection LevelTYPE II(DC), TYPE II(AC)
    Interface
    Communication InterfaceWIFI, RS485, CAN
    General Data
    Operating Temperature Range(℃)-40~60℃, >45℃ derating
    Permissible Ambient Humidity0-100%
    Permissible Altitude2000m
    Noise≤65 dB(A)
    Ingress Protection(IP) RatingIP65
    Inverter TopologNon-Isolated
    Over Voltage CategoryOVC II(DC), OVC III(AC)
    Cabinet Size (WxHxD mm) 527×894×294 (Excluding Connectors and Brackets)
    Weight (kg)80
    Type of CoolingIntelligent Air Cooling
    Warranty

    5 Years/10 Years

      the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

    Grid RegulationIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
    Safety / EMC StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2





    Please Contact Us!

    We will serve you the best products with the favorite prices


    ModelGSL-29.9KHV-3PHGSL-30KHV-3PHGSL-35KHV-3PH
    GSL-40KHV-3PHGSL-50KGV-3PH
    Battery Input Data

    Battery Type

    Li-Ion
    Battery Voltage Range (V)160~800
    Max.Charging Current (A)
    50+50
    Max.Discharging Current (A)
    50+50
    Number of Battery Input
    2
    Charging Strategy for Li-on Battery
    Self-adaption to BMS
    PV String Input Data
    Max.DC Input Power (W)3887039000455005200065000
    Max.DC Input Voltage (V)1000
    Start-up voltage (V)180
    MPPT Range (V)150-850
    Rated DC Input Voltage (V)600
    Max. Operating PV Input Current (A)36+36+3636+36+36+36
    Max. Input Short-Circuit Current (A) 55+55+5555+55+55+55

    No.of MPPT Trackers/ 

    No.of String Per MPPT Tracker

    3/2+2+24/2+2+2+2
    AC Output Data
    Rated AC Output and UPS Power (W)299003000035000
    4000050000
    Max. AC Output Power (W)29900
    330003850044000
    55000
    AC Output Rated Current (A)37.9/36.345.5/43.553.1/50.860.7/5875.8/72.5
    Max. AC Output Rated Current (A)45.4/43.450/43.558.4/55.866.7/63.883.4/79.7
    Max. Three-phase Unbalanced Output Current (A)606060
    7083.3
    Max. Continuous AC Passthrough (A)200
    Peak Power (off grid)1.5 time of rated power, 10 S
    Power Factor Adjustment Range0.8 leading to 0.8 lagging
    Rated Input/Output Voltage/Range (V)220/380V, 230/400V 0.85Un-1.1Un
    Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
    Grid Connection Form3L+N+PE
    Total Current Harmonic Distortion THDi<3% (of nominal power)
    DC Component of Grid<0.5% In
    Efficiency
    Max. Efficiency

    97.60%

    Euro Efficiency97.00%
    MPPT Efficiency99.00%
    Equipment Protection
    IntegratedDC Polarity Reverse Connection Protection, AC Output Overcurrent Protection AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
    Surge Protection LevelTYPE II(DC), TYPE II(AC)
    Interface
    Communication InterfaceWIFI, RS485, CAN
    General Data
    Operating Temperature Range(℃)-40~60℃, >45℃ derating
    Permissible Ambient Humidity0-100%
    Permissible Altitude2000m
    Noise≤65 dB(A)
    Ingress Protection(IP) RatingIP65
    Inverter TopologNon-Isolated
    Over Voltage CategoryOVC II(DC), OVC III(AC)
    Cabinet Size (WxHxD mm) 527×894×294 (Excluding Connectors and Brackets)
    Weight (kg)80
    Type of CoolingIntelligent Air Cooling
    Warranty

    5 Years/10 Years

      the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

    Grid RegulationIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
    Safety / EMC StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2





    Please Contact Us!

    We will serve you the best products with the favorite prices

    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    no data
     Service Tel: +86-755-84515360
     Address: A602, Tianan Cyber Park, Huangge North Road, Longgang District, Shenzhen, China
    GSL ENERGY - A leader of green energy provider in china since 2011

    0086 13923720280

    Contact us
    whatsapp
    contact customer service
    Contact us
    whatsapp
    cancel
    Customer service
    detect