An on-grid inverter’s main job is to convert DC power generated from the PV array into usable AC power. Hybrid inverters go a step further and work with batteries to store excess power as well. In the developing world, hybrid inverters are more of a necessity to compensate for weak or intermittent grids or a lack of grid electricity all together.

Add success, do you want to check your shopping cart?

暂无分享
B站不支持产品保障


ModelGSL-29.9KHV-3PHGSL-30KHV-3PHGSL-35KHV-3PH
GSL-40KHV-3PHGSL-50KGV-3PH
Battery Input Data

Battery Type

Li-Ion
Battery Voltage Range (V)160~800
Max.Charging Current (A)
50+50
Max.Discharging Current (A)
50+50
Number of Battery Input
2
Charging Strategy for Li-on Battery
Self-adaption to BMS
PV String Input Data
Max.DC Input Power (W)3887039000455005200065000
Max.DC Input Voltage (V)1000
Start-up voltage (V)180
MPPT Range (V)150-850
Rated DC Input Voltage (V)600
Max. Operating PV Input Current (A)36+36+3636+36+36+36
Max. Input Short-Circuit Current (A) 55+55+5555+55+55+55

No.of MPPT Trackers/ 

No.of String Per MPPT Tracker

3/2+2+24/2+2+2+2
AC Output Data
Rated AC Output and UPS Power (W)299003000035000
4000050000
Max. AC Output Power (W)29900
330003850044000
55000
AC Output Rated Current (A)37.9/36.345.5/43.553.1/50.860.7/5875.8/72.5
Max. AC Output Rated Current (A)45.4/43.450/43.558.4/55.866.7/63.883.4/79.7
Max. Three-phase Unbalanced Output Current (A)606060
7083.3
Max. Continuous AC Passthrough (A)200
Peak Power (off grid)1.5 time of rated power, 10 S
Power Factor Adjustment Range0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V)220/380V, 230/400V 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form3L+N+PE
Total Current Harmonic Distortion THDi<3% (of nominal power)
DC Component of Grid<0.5% In
Efficiency
Max. Efficiency

97.60%

Euro Efficiency97.00%
MPPT Efficiency99.00%
Equipment Protection
IntegratedDC Polarity Reverse Connection Protection, AC Output Overcurrent Protection AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch Overvoltage Load Drop Protection, Residual Current (RCD) Detection, Surge protection level
Surge Protection LevelTYPE II(DC), TYPE II(AC)
Interface
Communication InterfaceWIFI, RS485, CAN
General Data
Operating Temperature Range(℃)-40~60℃, >45℃ derating
Permissible Ambient Humidity0-100%
Permissible Altitude2000m
Noise≤65 dB(A)
Ingress Protection(IP) RatingIP65
Inverter TopologNon-Isolated
Over Voltage CategoryOVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 527×894×294 (Excluding Connectors and Brackets)
Weight (kg)80
Type of CoolingIntelligent Air Cooling
Warranty

5 Years/10 Years

  the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

Grid RegulationIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2





Please Contact Us!

We will serve you the best products with the favorite prices

Chat Online
Chat Online
Leave Your Message inputting...
Dear Sir, Thanks for your interest in GSL products. Please send your enquiry to Mr.Jim Deng at jimdeng@gsl-energy.com. If you need urgently reply, add whats app account: 0086 13923720280 Dear Sir, Thanks for your interest in GSL products. Please send your enquiry to Mr.Jim Deng at jimdeng@gsl-energy.com. If you need urgently reply, add whats app account: 0086 13923720280